Blog · Technical guidance
ALC Floor Panels on Beams and Purlins: How to Choose Purlin Spacing and Panel Thickness

Quick summary
- Do not choose an ALC floor panel from thickness alone.
- Confirm where the panel bears, the support spacing and the floor use.
- Bathtubs, tanks, safes and machines are concentrated loads and need separate checking.
Many customers begin with: “How much can a 150 mm ALC floor panel carry?” Thickness alone cannot answer that. The same panel works under different conditions when the beam and purlin layout changes.
Look at the whole floor system: where the panel bears, how far apart the supports are, and what the room will be used for.

1. Start with the panel type
Start by identifying the panel type for the intended use and support system. Check the length of 1,200–3,800 mm, width of 600 mm, thickness of 50/75/100/150/200 mm and one- or two-layer reinforcement mesh.
2. Where does the panel bear?
At the site, identify the two support lines below the panel and the direction in which the panel runs between them. They may be steel purlins, steel beams or bearing points on concrete beams.
If you cannot identify the bearing points, it is too early to select a panel. Bearing length, level and direction must match the approved drawing.

3. How far apart are the supports?
Purlin spacing is the distance between adjacent supports. With the same panel, 400 mm and 600 mm create different working spans, so deflection, vibration and internal forces also change.
Those two numbers explain the principle; they are not a universal load table. Measure the actual spacing or take it from the drawing.

4. What will the floor be used for?
A bedroom, storage area, technical room and roof do not have the same design condition. A full bathtub, fish tank, safe or machine is a concentrated load, not a uniformly distributed load, so its location should be reported before checking.

Need a quotation or technical advice?
Send HASS your plan, intended use and beam-purlin information for review during business hours.